System Sensor

System Sensor D2 Duct Detector, Conventional, 2 Wire, Photoelectric

(No reviews yet) Write a Review
SKU:
32246490
MPN:
D2
  • System Sensor D2 Duct Detector, Conventional, 2 Wire, Photoelectric, InnovairFlex, Rectangular
  • System Sensor D2 Duct Detector, Conventional, 2 Wire, Photoelectric, InnovairFlex, Rectangular
  • System Sensor D2 Duct Detector, Conventional, 2 Wire, Photoelectric, InnovairFlex, Rectangular
  • System Sensor D2 Duct Detector, Conventional, 2 Wire, Photoelectric, InnovairFlex, Square
  • System Sensor D2 Duct Detector, Conventional, 2 Wire, Photoelectric, InnovairFlex, Square
$295.00

Description

System Sensor BEAM1224S Beam Detector With Test, 4 Wire, Conventional, Single Ended

2-wire photoelectric duct smoke detector

The InnovairFlex™ Series are the only duct smoke detectors flexible enough to fit configurations from square to rectangular and everything in between.

Features:
• Photoelectric, integrated low-flow technology
• Air velocity rating from 100 ft/min to 4,000 ft/min (0.5 m/s to 20.32 m/sec)
• Versatile mounting options in square or rectangular configuration with modular construction
• Plug-in sensor
• Superb false alarm immunity with the latest sensor technology
• Broader ranges for operating temperature (−4°F to 158°F) and humidity (0% to 95% non-condensing)
• Patented sampling tube installs from front or back of the detector with no tools required
• A cover tamper feature to indicate a trouble condition for removed or improperly installed sensor cover
• Increased wiring space with a newly added ¾ inch conduit knockout
• Improved LED status
• 24 VDC
• Backward compatibility with existing Innovair products, including remote accessories

Specifications:

  • Air Duct Velocity:  100 to 4000 ft./min. (0.5 to 20.3 m/sec.)
  • Alarm Response Time:  15 sec.
  • Dimensions:  Rectangular: 14.38 in (37 cm) L; 5 in (12.74 cm) W; 2.5 in (6.36 cm) D Square: 7.75 in (19.7 cm) L; 9 in (22.9 cm) W; 2.5 in (6.36 cm) D
  • Input Capacitance:  0.1 μF max.​
  • Operating Humidity Range:  0% to 93% Relative Humidity Non-condensingOperating
  • Temperature Range:   -4°F to 158°F (-20°C to 70°C)
  • Power Supply Voltage:  8.5-35 VDC
  • Power Up Time:  35 sec. max.
  • Reset Time by Power Down:  0.3 sec. max.
  • Reset Time w RTS451:  .03 to 0.3 sec.
  • Reset Voltage:  2.5 VDC min.
  • Shipping Weight:  1.8 pounds; 0.82 kg
  • Storage Temperature:  -22°F to 158°F (-30°C to 70°C)
  • Wiring:  2-wire

The InnovairFlex D2 2-wire photoelectric duct smoke detector features a pivoting housing that fits various applications: both square and rectangular footprints mount to round or rectangular duct work.

This new duct smoke detector senses airflow speeds ranging from 100 to 4,000 feet per minute with proven System Sensor
precision. The enhancements built into this model improve false alarm immunity (with plug-in sensor head); broaden operating temperature (−4°F to 158°F) and humidity (0 to 95 percent noncondensing) ranges; while simplifying installation and maintenance.  These advance features can detect smoke even in the harshest duct applications.

The new design provides more wiring space with an added ¾ inch conduit knockout. Numbers and labels for terminal designations are consistent with previous Innovair models. The new sampling tube can be clicked into position with one smooth motion from either the front or the back of the detector.

The InnovairFlex D2 duct smoke detector has signals to indicate trouble and maintenance conditions. Additionally, a cover tamper feature is incorporated to indicate a trouble condition for removed or improperly installed sensor cover. An improved cover design, with an integrated the low-flow feature, isolates the sensor head from the low-flow technology for simple maintenance.

The InnovairFlex series is designed for greater flexibility and reliable smoke detection to simplify installation and maintenance. The new InnovairFlex product line is backward compatible to existing Innovair models, including remote test accessories


WARNING: Duct smoke detectors have specific limitations:

DUCT SMOKE DETECTORS ARE:
NOT a substitute for an open area smoke detector,
NOT a substitute for early warning detection, and
NOT a replacement for a building’s regular fire detection system.
Refer to NFPA 72 and 90A for additional duct smoke detector application information.

CLICK HERE FOR SPEC SHEET